Blown AWG Output

More
11 years 9 months ago #929 by david_sawatzke
Hello,
today I tried using the AWG of the xProtolab. On the intergrated Oscilloscope it didn't show any Output. I hooked my big analog Oscilloscope up and it showed that the Output signal was very low (0.1 Volt) and looked disturbed. Is there anything I can do to repair the AWG (I've already replaced the - 5V Source before).
David

Please Log in or Create an account to join the conversation.

More
11 years 9 months ago - 11 years 9 months ago #931 by ganzziani
Replied by ganzziani on topic Re:Blown AWG Output
Let's check this first:/\r\n//\r\n/1) Make sure the amplitude is set at max on the settings. Set the wave type to sinewave, with a frequency of 1kHz or so./\r\n/2) With your oscilloscope, measure pin 6 of the microcontroller, you should see your waveform with a 2V peak to peak amplitude.
Last edit: 11 years 9 months ago by ganzziani.

Please Log in or Create an account to join the conversation.

More
11 years 9 months ago #938 by david_sawatzke
Replied by david_sawatzke on topic Re:Blown AWG Output
At Pin 6 the MCU does give me a sinus Wave with approx. 2V peak to peak. But after the Resistor next to the pin (where the trace is going)it gives me only the slightest hint of a signal (at 5mv per division) at the wrong frequency.

Please Log in or Create an account to join the conversation.

More
11 years 9 months ago #941 by ganzziani
Replied by ganzziani on topic Re:Blown AWG Output
Probably the OPAMP is damaged.

Please Log in or Create an account to join the conversation.

More
11 years 7 months ago #999 by david_sawatzke
Replied by david_sawatzke on topic Re:Blown AWG Output
Well, it turns out it was the 180k resistor at the xmega output that was blown (resistance too high for my meter). Replaced it with a new one and now it works fine. Don't know how that happened. Hopefully that helps someone.

Please Log in or Create an account to join the conversation.

Time to create page: 0.161 seconds